F RY E R S
1VK65 SERIES
FREE STANDING GAS FRYER
INSTALLATION INSTRUCTIONS
1. A combination valve with pressure regulator is provided with
this unit.Natural Gas 4.0" (102 mm) W.C. Propane Gas 10.0"
(279 mm) W.C.
2. An adequate ventilation system is required for Commercial Cooking
Equipment. Information may be obtained by writing to the National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
When writing refer
to NFPA No. 96.
3. All models require a 6" (152 mm) clearance at both sides and rear
adjacent to combustible construction.All models require a 16"
(407 mm) minimum clearance to adjacent open top burner units.
4. This appliance is manufactured for commercial installation only and
is not intended for home use.
SERVICE CONNECTIONS:
1
⁄
2
" (13 mm) ID and
3
⁄
4
" (19 mm) OD rear gas connection.
NEMA 5-15P 120 Volt cord & plug supplied with fryers.
NOTE: In line with its policy to continually improve its product,
Vulcan reserves the right to change materials and specications
without notice.
MODEL Width Depth
Overall
Height
Working
Height Tank Size BTU/hr.
Fry Comp.
Capacity
Approx.
Shipping Weight
1VK65A
1VK65D
1VK65C
21" 34
3
⁄
8
" 47
1
⁄
8
" 36
1
⁄
4
" 19.5" x 14" 80,000 65 - 70 lbs. 235 lbs.
This appliance is manufactured for commercial use only and is not intended for home use.
a division of ITW Food Equipment Group LLC
P.O. Box 696
■
Louisville, KY 40201
■
Toll-free: 1-800-814-2028
■
Local: 502-778-2791
■
Quote & Order Fax: 1-800-444-0602
F4 536 6 (10/11)
Central Restaurant Products