- SUPPLY RISER - Supply Riser with Volume Dampers
- 1/2 Pint Grease Cup New Style, Flanged Slotted
Fire System #1
ANSUL-3.0/1.5 Ansul 4.5 gallon Wall Mounted Fire System (includes pre-piped hood
(s) with detection)
Fan #1
Exhaust Fan Belt Drive Centrifugal Upblast Exhaust Fan with 20.75" wheel Exhaust
Fan handles 3162 CFM @ -1.000" wc.
Exhaust Motor: 1.500 HP, 3 Phase 208 V, 4.7 FLA.
- Grease Cup for kitchen-duty centrifugal exhaust fans.
Fan #2 - Heater
Electric Heated Make Up Air Unit with 15" Blower and a 4 stage total, 1 modulating,
45kw 208-3 Coil
Supply Fan handles 2846 CFM @ 0.500" wc.
Heater supplies 109216 BTUs.
Supply Motor: 0.750 HP, 3 Phase 208 V, 2.7 FLA
- Sloped Foam Filtered Intake for Size #2 Modular Heater.
- 50-80°F Discharge Temp Control
Cooling Interlock Relay. 24VAC Coil. 120V Control
Curb for Fan #1 - Exhaust Fan
- Hinged Base for Curb. Standard Hinge attached to curb
Curb for Fan #2
- Heater Curb Insulated On Fan # 2
Electrical System #1
3 Phase, W/ 1 Exhaust Fan, 1 Supply Fan, Exhaust in Fire, Fan
On/Off Thermostatically Controlled. Includes 2 Duct Thermostat sets
BACKSPLASH 80.00" High X 138.00" Long 430 SS
FIELD WRAPPER 17.00" High Front, Left, Right
Motorized Back Draft Damper 22.75' X 24" for Size 2 Standard and Modular, Heaters
with Extended Shaft.
Accessories:
1 ea Hood Installation: F.E.C to have Exhaust System installed by Local
and State Codes of Tennessee to meet Exhaust Hood Mechanical
Codes. All Plans, Submittals and Permit Fees are the responsibility of
the F.E.C. 1. Hood should be installed with 18 clearance to
combustibles or use clearance reduction methods from Table 308.6
I.M.C.
2. Non combustible drywall wall covered with minimum 24 ga.
Stainless steel under Hood and 18 past hood in all directions 0
clearance
3. 16 ga steel exhaust duct all welded seams welded to hood Liquid
Tight
4. 2 layers ' 0' clearance duct wrap on exhaust duct within 18" of
combustible material
5. 24 ga. Galvanized make up air duct (no flex duct within 18" of hood
Note: Hood Installed, excluding Roof Curb Flashing and any and all
Electric Connections.
Kitchen Equip. No. 19 - Range, Restaurant, Electric (1 REQ'D)
Vulcan Hart Model E60FL or approved equal.
Range, 60" Restaurant, Electric, (6) 2kw French Hot Plates 9 1/2" round French