INSTALLATION INSTRUCTIONS
BEFORE INSTALLATION:
Adequate ventilation should be provided, preferably by a
hood with vent and exhaust fan. Never make a direct flue
connection between flue or fryer and vent flue unless a
flue diverter is used and sometimes this is not satisfac-
tory. Venting into a hood is preferable. There must be
sufficient clearance between doors and openings to
move equipment into the kitchen.
UNPACKING - ASSEMBLING
Uncrate the unit carefully and place in the approximate
position it will occupy in the battery. Fry baskets, crumb
screen, and basket hanger assembly are packed with
fryer.
INSTALLATION:
Set fryer in position and level front to rear and right to left.
Gas connection (1/2") is provided at rear.
ELECTRICAL CONNECTIONS
A 120 volt 3 wire cycle supply cord is supplied at the rear
on all "E" units ("G" units require no electrical
connections). Multiple units, batteried at the factory, are
equipped with a single electric supply cord.
IMPORTANT: Pipe joint compounds used when connect-
ing appliances to gas should be resistant to the action of
propane gas. Pipe joints should be tested for leaks with a
soap and water solution before operating the unit.
All 7400 and 7500 series units are equipped with a
factory installed rear flue box back heat shield. Heat
shield is required when unit is installed next to
combustible surface. A minimum 6" clearance to back
and sides of combustible surface must be maintained at
all times.
PILOT LIGHTING INSTRUCTIONS
TO PLACE IN OPERATION:
1. Make sure the thermostat dial and the combination
dial (or lever) are in the "OFF" position.
2. Turn "ON" main gas supply.
3. Turn gas valve in unit (just above the combination
valve) "ON".
LIGHTING PILOT:
1. Turn gas cock dial (or lever) on combination valve to
"PILOT" position.
2. Depress gas dial (or lever) and light pilot; with pilot
burning, hold gas cock dial depressed for approxi-
mately 30 seconds before releasing.
NOTE: If pilot does not remain lit, repeat step #2 after
waiting 5 minutes to allow gas which may have accumu-
lated in the burner compartment to escape. Allow a
longer period of time before releasing gas dial (or lever)
(adjust pilot flame if necessary).
3. Turn gas cock dial to "ON" position.
4. Flip power supply toggle switch into up position
(7594E, 7595E, 7494E & 7495E units only).
5. Turn thermostat to desired temperature position.
TEMPORARY SHUT DOWN:
See Details 1 & 1A
1. To turn unit "OFF", flip power supply toggle switch to
down position (7594E, 7595E 7494E & 7495E units
only).
2. Turn thermostat to "OFF" position.
3. Turn dial (or lever) on combination valve to "OFF" pos-
ition.
DETAIL 1 DETAIL 1A
SEASONAL SHUT DOWN:
1. To turn unit "OFF", flip power supply toggle switch to
down position (7594E, 7595E, 7494E, & 7495E units
only).
2. Turn thermostat to "OFF" position.
3. Turn dial (or lever) on combination valve to "OFF" pos-
ition.
4. Turn gas valve above combination valve to "OFF" pos-
ition.
NOTE: To place unit back into operation, refer to Lighting
Instructions above.
114590-4