INSTALLATION & OPERATION MANUAL GAS & ELECTRIC TILTING BRAISING PANS VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-06
INSTALLATION DIAGRAM — ELECTRIC HEAT BRAISING PANS DIMENSIONS - INCHES Model No. A B C D E-30-C 36 39 1/2 11 1/2 66 E-40-C 48 39 1/2 11 1/2
OPERATION WARNING: THE TILTING BRAISING PAN AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING THE BRAISING PAN. BEFORE FIRST USE U
7. Lower the braising pan (see OPERATION OF LIFTING SYSTEM in this manual). The braising pan will not operate with the pan in the "up" pos
DO NOT use the braising pan as a deep fat fryer; use it only for shallow pan frying (cooking oil film not more than 1/8" thick). Its use for deep
Do not overheat the clad stainless steel plate by setting the temperature well above recommended temperatures, or by operating the braising pan withou
1. Close all front doors. 2. Press the upper half of the rocker switch to raise the braising pan and the lower half of the rocker switch to lower
STEAMING INSERTS (Optional) Your tilting braising pan can be used for steaming frozen and fresh foods. The 30-gallon pans (Models E or G30) can be loa
CLEANING WARNING: DISCONNECT ELEC
COOKING GUIDELINES The guidelines given below are suggested quantities, temperature settings, and estimated numbers of orders per load and per hour. W
ITEM PORTION SIZE TEMP. (°F) BATCHES PER HOUR G/E300/C PER LOAD QTY. PORTIONS G/E400/C PER LOAD Q
IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-U
ITEM PORTION SIZE TEMP. (°F) BATCHES PER HOUR G/E300/C PER LOAD QTY. PORTIONS G/E400/C PER LOAD QTY. PORTIONS CHICKEN
MAINTENANCE WARNING: THE TILTING BRAISING PAN AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING THE BRAISING PAN. WARNING: DISCONN
Door Hinges Lubricate the front door hinges with a silicone spray lubricant every 6 months. Spray the lubricant on the hinge pin at the top and bottom
TROUBLESHOOTING GAS HEAT BRAISING PANS PROBLEM POSSIBLE CAUSES Burners do not come on. 1. Gas supply to braising pan is OFF. 2. Manual gas shutoff
TABLE OF CONTENTS GENERAL 4 INSTALLATION 4 Unpacking 4 Location 5 Installation Codes and Standards 6 Leveling and Anchoring
Installation, Operation and Care of TILTING BRAISING PANS MODELS G300, G400, G30C, G40C, E300, E400, E30C, & E40C KEEP THESE INSTRUCTIONS FOR FUT
LOCATION For Gas Powered Braising Pans Only The braising pan must be kept free and
INSTALLATION CODES AND STANDARDS Your Vulcan Tilting Braising Pan must be installed in accordance with: In the United States: 1. State and local cod
SERVICE CONNECTIONS To reach service and utility connections, remove the left side panel. To remove, hold the panel from underneath and lift it up. Wh
INSTALLATION DIAGRAM — GAS HEAT BRAISING PANS — 8 — DIMENSIONS - MILLIMETERS Model No. A B C D G-30-C 914 1003 292 1676 G-40-C 121 1003
ELECTRICAL CONNECTIONS (see Fig. 3) WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL COD