HEAVY DUTY ELECTRIC RANGES, 12" WIDE
FULL BODY EXPANDO RANGES
F-31589 (10-03)
FULL BODY EXPANDO RANGE POWER SUPPLY:
208 volts, 60 Hz, 1 ph with magnetic circuit breakers.
208 volts, 60 Hz, 3 ph with magnetic circuit breakers.
240 volts, 60 Hz, 1 ph with magnetic circuit breakers.
240 volts, 60 Hz, 3 ph with magnetic circuit breakers.
480 volts, 60 Hz, 1 ph (overload protection not included).
480 volts, 60 Hz, 3 ph (overload protection not included).
VEX
208/240 VOLT
TOTAL LOAD KW PER PHASE
KW 3-PHASE
UNIT CONN. L1–L2 L2L3 L1–L3
VEX2 5
VEX3 4 2.0 2.0
NORMAL AMPS PER LINE
3-PHASE 1-PHASE
208V 240V 208V 240V
L2 L2 L3 L1 L2 L3 L1-L2 L1-L2
VEX2 24 21
VEX3 8 17 8 7 14 7 19 17
TOTAL LOAD KW PER PHASE
KW 3-PHASE
UNIT CONN. X–Y Z Y–Z
VEX2 5
VEX3 4 2.0 2.0
NORMAL AMPS PER LINE
3-PHASE 1-PHASE
480V 480V
XYXXZ
VEX2 10.4
VEX3 3.6 7.2 3.6 8.3