BOIL OUT
BOIL OUT heats water in the vat for cleaning
purposes for 15 minutes. If operating at a higher
altitude, the boiling temperature may be lowered.
DISPLAY INSTRUCTION
READY Press 2 & 3 simultaneously.
-FUNCTIONS- Press
.
EDIT PRODUCT Press
.
SEL SETBACK Press
.
CALIBRATE Press
.
BOIL OUT Press ENTER.
START BOIL - To change boil temperature,
press
.
CH BOIL TEMP Press ENTER.
TEMP = 195°F Alter boil temp. Use .
When OK, Press EXIT.
CH BOIL TEMP Press
.
START BOIL
- To begin boil, press ENTER.*
BOIL OUT
TIME = 15:00 Time Counts down or EXIT.
DRAIN VAT Suspends operation. Turn
fryer OFF.
* To return to -FUNCTIONS- press EXIT.
RECOVERY
Displays the previous recovery time, the time it takes
to recover from 275 to 325°F.
DISPLAY INSTRUCTION
READY Press 2 & 3 simultaneously.
-FUNCTIONS- Press
.
EDIT PRODUCT Press
.
SEL SETBACK Press
.
CALIBRATE Press
.
BOIL OUT Press
.
RECOVERY Press ENTER.
REC TM = XX:XX Press EXIT.
-FUNCTIONS- Press EXIT.
READY
SELECT MELT
▲▼ toggles MELT DISABLE or MELT ENABLE.
ENABLE is required when using solid shortening to
automatically MELT if below 135°F.
DISPLAY INSTRUCTION
READY Press 2 & 3 simultaneously.
-FUNCTIONS- Press
.
EDIT PRODUCT Press
.
SEL SETBACK Press
.
CALIBRATE Press
.
BOIL OUT Press
.
RECOVERY Press
.
SELECT MELT Press ENTER.
MELT ENABLE Press
or to toggle.
MELT DISABLE When OK, press EXIT.
SELECT MELT Press EXIT.
-FUNCTIONS- Press EXIT.
READY
MANUAL SETUP
▲▼ toggles MANUAL ON or MANUAL OFF. ON
allows time/temp entry for the batch. OFF disables
manual operation and allows the manual pad (9) to
be reprogrammed as a regular product pad.
DISPLAY INSTRUCTION
READY Press 2 & 3 simultaneously.
-FUNCTIONS- Press
.
EDIT PRODUCT Press
.
SEL SETBACK Press
.
CALIBRATE Press
.
BOIL OUT Press
.
RECOVERY Press
.
SELECT MELT Press
.
MANUAL SETUP Press ENTER.
MANUAL OFF Press
or to toggle.
MANUAL ON When OK, press EXIT.
MANUAL SETUP Press EXIT.