Fig. 3 Fig. 4
REAR OF TOP OVEN
KNOCK OUT WELDED PLATE
FOR FLUE EXTENSION INSTALLATION
BOTTOM
LOCATING STUDS
PL-52992
FRONT OF TOP OVEN
Remove the two
7
16" (11.1mm) knockouts on each side of the top cover and place oven in upright position at
installation location. Turn the adjustable feet in or out to level the oven front-to-back and side-to-side (see
LEVELING on page 6).
Remove right-hand side panels from both ovens. Remove welded plate from bottom of upper oven (Fig. 3).
Install the two locating studs (included in the leg stack set) into screw plates on underside of upper oven (Fig. 3).
Place upper oven on top of lower oven using the locating studs.
Remove flue extension from upper oven. Install long flue extension into existing right-angled flue extension in
lower oven. Attach long flue extension to wall of upper oven using screws provided. Secure chimney to roof of
upper oven (Fig. 4).
Install right side panels on both ovens. Connect the piping between the top oven and bottom oven. Pipe
compound must be suitable for the type of gas being used (natural or propane).
The manual gas valve at the bottom of the control panel should remain off until all electrical connections are made
and the ovens are checked or used.
RIGHT ANGLED
FLUE EXTENSION
LONG FLUE
EXTENSION
CHIMNEY
PL-52221